34.
When the diagnostic operating instructions are displayed, complete the following steps:
1.
Press Enter.
2.
Select the
Task Selection
option.
Note:
If the terminal type is not defined, you are prompted to
define it before you can proceed.
3.
Select the
Log Repair
option.
4.
Select the resource associated with the repair action:
v
If the repair action was reseating a cable or adapter, select the
resource associated with that repair action.
v
If the resource associated with your repair action is not
displayed on the Resource List, select
sysplanar0
.
5.
Click
Commit
after you make your selection.
35.
Exit from diagnostics in this partition and return to the AIX command prompt.
36.
Have all the partitions in the list of A
xx
partitions you began recording in step 14 on page 195 been
processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 32 on page 196 to process the next partition in the list you recorded in step 14 on page 195.
37.
If the system attention LED is still on, turn off the LED as described in “Activating and deactivating
LEDs.”
This completes the repair
. Return the system to the customer.
Note:
If, during the processing of the list of open service action events, some service action events remained open,
further service actions might be required to complete the repair.
Activating and deactivating LEDs
You can use these procedures to activate or deactivate light-emitting diodes (LEDs) by using the
management console or the Advanced System Management Interface (ASMI).
For IBM Power Systems servers that contain the POWER7 processor, the LEDs can be used to identify or
verify a part that you are servicing. The error and identify function (amber) LED indicates an error and
corresponds to the location code in the system reference code (SRC). The LED is activated and
deactivated automatically.
Additionally, the following procedures can also be used to activate and deactivate LEDs.
v
“Deactivating a system attention LED or partition LED by using the management console”
v
“Activating or deactivating an identify LED by using the management console” on page 198
v
v
Deactivating a system attention LED or partition LED by using the
management console
You can deactivate a system attention LED or a logical partition LED if you decide that a problem is not
a high priority and you decide to repair the problem at a later time. You can do this task from the
Hardware Management Console (HMC) or the IBM Systems Director Management Console (SDMC).
Common procedures for installable features
197
Содержание Power 720 Express 8202-E4B
Страница 2: ......
Страница 10: ...viii Disk drives or solid state drives ...
Страница 226: ...210 Disk drives or solid state drives ...
Страница 227: ......
Страница 228: ... Printed in USA ...