1.
Complete the prerequisite tasks. For instructions, see “Before you begin” on page 137.
2.
Find the package that contains the new drive.
Attention:
Drives are fragile. Handle with care.
3.
Remove the drive from the static-protective package.
4.
Proceed to preparing to replace a drive by using the iprconfig command.
Preparing to replace a disk drive or solid-state drive by using the iprconfig
command
Complete the following steps before you replace a disk drive or solid-state drive by using the iprconfig
command:
1.
From the IBM Power RAID Configuration Utility display, select
Work with disk unit recovery
. Press
Enter.
2.
From the Work with Disk Unit Recovery display, select
Concurrent add device
. Press Enter.
A Concurrent Device Add display similar to the following example is shown.
3.
Type
1
(Select) next to the location from which you removed the disk drive or solid-state drive.
The Verify Device Concurrent Add display is shown. The service indicator flashes for that drive slot.
Choose from the following options:
v
If you are replacing a drive in a system or expansion unit, proceed to “Replacing a disk drive or
solid-state drive in the 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D system or
expansion unit.”
v
If you are replacing a drive in the 5888 PCIe storage enclosure, proceed to “Replacing a solid-state
drive in the 5888 PCIe storage enclosure” on page 70.
v
If you are replacing a drive in the EDR1 PCIe storage enclosure, proceed to “Replacing a solid-state
drive in the EDR1 PCIe storage enclosure” on page 71.
Replacing a disk drive or solid-state drive in the 8202-E4B, 8202-E4C, 8202-E4D,
8205-E6B, 8205-E6C, or 8205-E6D system or expansion unit
Complete the following steps to replace a disk drive or solid-state drive in a system or in an expansion
unit:
Concurrent Device Add
Choose a single location for add operations
1=Select
OPT Name
Platform Location
Description
Status
--- ------ -------------------------- ------------------------- ----------------
U5887.001.Z065075-P1-D1
Empty
U5887.001.Z065075-P1-D6
Empty
U5887.001.Z065075-P1-D7
Empty
U5887.001.Z065075-P1-D8
Empty
U5887.001.Z065075-P1-D9
Empty
e=Exit
q=Cancel
t=Toggle
Figure 45. Example Concurrent Device Add display