Preparing the system
If you are removing a drive in order to install a new or upgraded drive, see “Installing a disk drive or
solid-state drive in the 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D with the IBM i
system or logical partition power turned on” on page 20. If you are removing a drive as part of a service
procedure, continue to use the following procedure.
1.
Complete the prerequisite tasks. For instructions, see “Before you begin” on page 137.
2.
If applicable, remove the system unit door, remove the expansion unit door, or open the rack.
3.
Remove the front cover:
v
For instructions for a rack-mounted system, see “Removing the front cover from a rack-mounted
system” on page 151.
v
For instructions for a stand-alone system, see “Removing the front cover from a stand-alone
8202-E4B, 8202-E4C, 8202-E4D, or 8205-E6B system” on page 152.
4.
Locate the disk drive to be replaced and record the location information. Then, use the location
information to activate the identify light for that disk drive. For instructions, see Identifying a failing
part in an IBM i system or logical partition
Preparing to remove a disk drive by using the HSM
1.
If you are removing a solid-state device that is located on a PCIe RAID and SSD SAS adapter, go to
Removing and replacing the PCIe RAID and SSD SAS adapterRemoving and replacing the PCIe
RAID and SSD SAS adapter and complete that procedure, then return here and Complete the
following steps.
2.
Type
strsst
on the command line of the IBM i session in the Hardware Service Manager (HSM) and
press Enter.
3.
Type your service tools user ID and service tools password on the
Start Service Tools (STRSST)
Sign On display, and press Enter.
4.
Select
Work with disk units
from the System Service Tools display, press Enter.
5.
Select
Display Disk Configuration
from the Work with Disk Units display, and press Enter.
6.
Select
Display non-configured units
from the Display Disk Configuration display, and press Enter.
7.
Is the failed drive a non-configured unit?
v
v
Yes: Determine if the disk drive to be removed was replaced by a hot spare when it failed. A
xxxx9031 error logged close to the same time of the original disk failure indicates the automatic
Rebuild of the data to a hot spare device, then go on to the next step.
8.
Is the disk drive to be removed controlled by the load source adapter?
v
No: Go to step 11.
v
Yes: Go to the next step.
9.
Is the disk drive to be removed located in a valid load source position?
v
v
Yes: Go to step 11.
10.
Choose the concurrent maintenance option. This option shows the disk drive location on the
concurrent maintenance display. Go to step 13 on page 54.
11.
Select
Device Concurrent Maintenance
from the Hardware Service Manager display. Press Enter.
The Device Concurrent Maintenance display is shown, as shown in the following figure.
Disk drives or solid-state drives
53
Содержание Power 720 Express 8202-E4B