10.
Type
iprconfig
on the command line and press Enter.
The IBM Power RAID Configuration Utility display is shown.
11.
Select
Display hardware status
from the IBM Power RAID Configuration Utility display. Press Enter.
The Display Hardware Status display is shown.
12.
Look for the drive at the PCI location you recorded. The drive might have a Failed status.
13.
If the drive you want to replace is unprotected or in use, move the data from the drive before
continuing with this procedure.
For PCI-X controller information, see the
PCI-X SCSI RAID Controller Reference Guide for Linux
. This
guide is available from the SCSI PCI Adapters web page.
For SAS RAID controller information, see the SAS RAID controllers for Linux topic.
14.
Type
1
(Display hardware resource information details) next to the drive you want to replace. Press
Enter.
The Disk Unit Hardware Resource Information Details is displayed like the shown in the following
sample.
Display Hardware Status
Type option, press Enter.
1=Display hardware resource information details
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- ----------------
0000:01:00.0/0:
PCI-E SAS RAID Adapter
Operational
0000:01:00.0/0:0:0:0
Advanced Function SSD
Active
0000:01:00.0/0:0:1:0
Advanced Function SSD
Active
0000:01:00.0/0:0:2:0
Advanced Function SSD
Active
0000:01:00.0/0:0:3:0
Advanced Function SSD
Active
0000:01:00.0/0:0:4:0
Advanced Function SSD
Active
0000:01:00.0/0:0:5:0
Advanced Function SSD
Failed
0000:01:00.0/0:0:6:0
Advanced Function SSD
Active
0000:01:00.0/0:0:8:0
Enclosure
Active
0000:01:00.0/0:0:9:0
Enclosure
Active
0001:01:00.0/1:
PCI-E SAS RAID Adapter
Operational
0001:01:00.0/1:0:3:0
Advanced Function SSD
Remote
0001:01:00.0/1:0:4:0
Advanced Function SSD
Remote
0001:01:00.0/1:0:5:0
Advanced Function SSD
Remote
More...
e=Exit
q=Cancel
r=Refresh
t=Toggle
f=PageDn
b=PageUp
Figure 83. Example Display Hardware Status