2627-201
Explanation:
Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
Response:
Failing Item:
v
CABLE
v
NETWORK
2627-301
Explanation:
Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
5.
Go to Performing the checkout procedure.
Response:
Failing Item:
v
CABLE
v
NETWORK
v
2627-701
Explanation:
Error Log Analysis indicates that this adapter has failed due to an internal error. Replace the IBM Flex
System IB6132 QDR InfiniBand Adapter.
Response:
Failing Item:
v
2627-702
Explanation:
Error Log Analysis indicates that this adapter has failed due to a failure with the uplink interface used
to connect this device to the host processor. Replace the IBM Flex System IB6132 QDR InfiniBand Adapter.
Response:
Failing Item:
v
2627-201 • 2627-702
Chapter 8. Troubleshooting
339
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...