2607-XXX
Explanation:
Generic reference for 8Gb PCIe Fibre Channel Expansion Card. Go to Performing the checkout
Response:
Failing Item:
v
2624-101
Explanation:
Configuration failure. Replace the 4X PCI-E DDR InfiniBand Host Channel Adapter.
Response:
Failing Item:
v
2624-102
Explanation:
Queue pair create failure. Replace the 4X PCI-E DDR InfiniBand Host Channel Adapter.
Response:
Failing Item:
v
2624-103
Explanation:
Loop back test failure. Replace the 4X PCI-E DDR InfiniBand Host Channel Adapter.
Response:
Failing Item:
v
2624-201
Explanation:
Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
Response:
Failing Item:
v
CABLE
v
NETWORK
2607-XXX • 2624-201
Chapter 8. Troubleshooting
333
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...