BA130015
Explanation:
USB CD-ROM in the media tray: ATA/ATAPI packet command execution failed.
Response:
1.
Remove the CD or DVD in the drive and replace it with a known-good disk.
2.
Retry the operation.
3.
Reboot the server.
4.
Troubleshoot the media tray and CD-ROM drive.
5.
Replace the USB CD or DVD drive.
6.
Reboot the server.
7.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA131010
Explanation:
The USB keyboard has been removed.
Response:
1.
Reseat the keyboard cable in the management module USB port.
2.
Check for server firmware updates; then, install the updates if available.
BA140001
Explanation:
The SCSD read/write optical test unit ready failed; hardware error.
Response:
1.
Troubleshoot the SCSD devices.
2.
Verify that the SCSD cables and devices are properly plugged. Correct any problems that are found.
3.
Replace the SCSD cables and devices.
4.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA140002
Explanation:
The SCSD read/write optical test unit ready failed; sense data available.
Response:
1.
Troubleshoot the SCSD devices.
2.
Verify that the SCSD cables and devices are properly plugged. Correct any problems that are found.
3.
Replace the SCSD cables and devices.
4.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA130015 • BA140002
Chapter 8. Troubleshooting
205
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...