BA01B013
Explanation:
The discover mode is invalid
Response:
1.
Reboot the server.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA01B014
Explanation:
Closing the BOOTP node failed
Response:
1.
Reboot the server.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA01B015
Explanation:
The BOOTP discover server timed out
Response:
Perform the following actions that checkpoint CA00E174 describes:
1.
Verify that:
v
The bootp server is correctly configured; then retry the operation.
v
The network connections are correct; then retry the operation.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA01D001
Explanation:
Opening the DHCP node failed
Response:
1.
Reboot the server.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA01D020
Explanation:
DHCP failed to read from the network
Response:
1.
Verify that the network cable is connected, and that the network is active.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA01B013 • BA01D020
Chapter 8. Troubleshooting
191
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...