BA030011
Explanation:
RTAS attempt to allocate memory failed
Response:
1.
Reboot the server.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA04000F
Explanation:
Self test failed on device; no error or location code information is available
Response:
1.
Reboot the server.
2.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA040010
Explanation:
Self test failed on device; can't locate package.
Response:
1.
If a location code is listed with the error, replace the device specified by the location code.
2.
If a location code was not listed with the error: Search RETAIN tips and the firmware change history for the
reference code to determine the recommended actions. If a firmware update is needed, see Updating the firmware
BA040020
Explanation:
The machine type and model are not recognized by the server firmware.
Response:
1.
Reboot the server.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA040030
Explanation:
The firmware was not able to build the UID properly for this system. As a result, problems may occur
with the licensing of the AIX operating system.
Response:
1.
Reboot the server.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA030011 • BA040030
194
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...