B7006955
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B7006956
Explanation:
An NVRAM failure was detected.
Response:
Go to Isolating firmware problems.
B7006965
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B7006970
Explanation:
PCI host bridge failure
Response:
1.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
B7006971
Explanation:
PCI bus failure
Response:
1.
Use the PCI expansion card (PIOCARD) problem isolation procedure to determine the failing component.
2.
If the problem persists, replace the system-board and chassis assembly, as described in Replacing the
system-board and chassis assembly.
B7006972
Explanation:
System bus error
Response:
Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
B7006973
Explanation:
System bus error
Response:
1.
Use the PCI expansion card (PIOCARD) problem isolation procedure to determine the failing component.
2.
If the problem persists, replace the system-board and chassis assembly, as described in Replacing the
system-board and chassis assembly.
B7006955 • B7006973
172
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...