![IBM eServer 250 xSeries Скачать руководство пользователя страница 131](http://html2.mh-extra.com/html/ibm/eserver-250-xseries/eserver-250-xseries_user-reference-manual_4064779131.webp)
Chapter 6. Solving problems
117
089
Microprocessor Failed
Invalid microprocessor in slot xyz or BIOS setup
problem
(where xyz identifies the microprocessor that is
causing the error message)
1.
Check the system
error log for the
related error
messages.
2.
If your server
does not have the
latest level BIOS
installed, update
the BIOS.
3.
If the problem
remains, replace
the xyz
microprocessor
and run the test
again.
If the problem
persists, call for
service.
Processor in socket id xyz is installed but not
functioning
(where xyz identifies the microprocessor that is
causing the error message)
Microprocessor in socket id xyz
(where xyz identifies the microprocessor that is
causing the error message)
Note:
The Microprocessor Error LED
associated with the microprocessor will
be lit.
1.
Reseat the
microprocessor.
2.
If the problem
remains, replace
the
microprocessor.
If the problem
persists, call for
service.
Processor in socket id xyz is defective
(where xyz identifies the microprocessor that is
causing the error message)
Replace the
microprocessor.
If the problem
persists, call for
service.
Code
Function
Result
Text message
Action
Содержание eServer 250 xSeries
Страница 1: ...User s Reference xSeries 250...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 250 User s Reference SC21 P902 00...
Страница 8: ...vi IBM xSeries 250 User s Reference...
Страница 14: ...xii IBM xSeries 250 User s Reference...
Страница 24: ...10 IBM xSeries 250 User s Reference...
Страница 36: ...22 IBM xSeries 250 User s Reference...
Страница 108: ...94 IBM xSeries 250 User s Reference...
Страница 185: ......
Страница 186: ...IBM Part Number 21P9020 Printed in the United States of America 21P9 2...