Chapter 6. Solving problems
141
pnt0-2
PCI search specified, PCI device not found!
Explanation:
The driver cannot locate the Ethernet controller on the PCI bus.
Action:
•
Run the NETCONFIG program to search for another Ethernet controller
•
Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the
diagnostic programs.
pnt0-6
Cannot allocate memory for the adapter during an interrupt. Please check your Streams
parameters.
Explanation:
On a SunSoft Solaris system, this message indicates that the system is out of
Streams memory blocks.
Action:
Use the CRASH utility to increase the number of Streams memory blocks. Modify the
interrupt request (IRQ) settings in the Configuration/Setup Utility program, or run the
NETCONFIG program to match the hardware settings.
pnt0-7
Cannot allocate memory for the adapter during reset. Please check your Streams parameters.
Explanation:
The system is out of Streams memory blocks.
Action:
Use the CRASH utility to increase the number of Streams memory blocks.
pnt0-11
Device not found!
Explanation:
The driver cannot find an Ethernet controller.
Action:
Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the
diagnostic programs.
pnt0-12
Device failed checksum test!
Explanation:
The driver cannot find an Ethernet controller.
Action:
Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the
diagnostic programs.
pnt0-13
add_intr_handler failed! Interrupts already enabled.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings.
pnt0-14
Cannot locate hardware.
Explanation:
The SunSoft Solaris driver cannot find any Ethernet controller.
Action:
Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the
diagnostic programs.
pnt0-15
No more devices to open.
Explanation:
The SunSoft Solaris driver cannot find any more Ethernet controllers.
Action:
Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
pnt0-17
Device fault...Reset initiated!
Explanation:
The SunSoft Solaris driver has been reset due to a device fault.
Action:
Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
Table 24. UNIX LLI driver messages for the Ethernet controller.
Содержание eServer 250 xSeries
Страница 1: ...User s Reference xSeries 250...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 250 User s Reference SC21 P902 00...
Страница 8: ...vi IBM xSeries 250 User s Reference...
Страница 14: ...xii IBM xSeries 250 User s Reference...
Страница 24: ...10 IBM xSeries 250 User s Reference...
Страница 36: ...22 IBM xSeries 250 User s Reference...
Страница 108: ...94 IBM xSeries 250 User s Reference...
Страница 185: ......
Страница 186: ...IBM Part Number 21P9020 Printed in the United States of America 21P9 2...