ibaBM-PN
Manual
Issue 1.9
45
9.2.6
„Sniffer“ module
The sniffer module is only available underneath a TAP node.
9.2.6.1 „General“ tab
Figure 27: „Sniffer“ module – „General“ tab
Basic settings
Module type, Locked, Enabled, Name, Timebase, Use name as prefix
see chapter 9.2.1.1.
Module N
o
.
Logical module no. for clearly referencing of signals, e.g. in expressions in virtual
modules and ibaAnalyzer
Module Layout
No. analog signals
Defining the number of analog signals for this module (max. 1000)
No. digital signals
Defining the number of digital signals for this module (max. 1000)
PROFINET
Device name
Assignment of the module to a device, the selectable devices are listed under
"TAP".