9.2.1.1 "General“ tab
Figure 14: "ibaBM-PN“ module – “General“ tab
Basic settings
Module type
(only read)
Display of the module type
Locked
A module can be locked in order to prevent accidental or unauthorized changes in
the module settings.
Enabled
Disabled modules are excluded from signal acquisition.
Name
Enter here the name for the module as clear text.
Timebase
Timebase for the data acquisition which is used for this device in ms. Cycles of
down to 0.125 ms are possible (depending on the number of the signals).
Use name as prefix
The module name is placed in front of the signal name as prefix.
Connection
IP address
IP address of the device (via FO); cannot be changed.
Auto enable/disable
If the value is TRUE, the data acquisition is started even though the device is miss-
ing. The missing device is temporarily disabled in the configuration. During the
measurement process, ibaPDA tries to re-establish the connection to the missing
device. If this is successful, the measurement is restarted automatically including
the device that has been missing. If the value is FALSE, the measurement will not
be started, in case ibaPDA cannot establish a connection to the device.