2-43
Relief valve operation
First stage
At the start of operation, the shockless piston moves to maintain the spring chamber at a low
pressure. Thus, the pressure receiving area of the poppet becomes the poppet seat area (S1), a
considerably larger area than the pressure receiving area (S1-S2) at the specified relief setting.
For this reason, the relief operating pressure is kept at a low pressure until the shockless piston
completes its movement.
The low pressure holding time depends on the poppet orifice diameter, the free piston pressure
receiving area and the free piston stroke.
S2
S1
Shockless piston
R35Z72SM06
Η
Second stage
When the shockless piston completes its movement, the pressure inside the spring chamber
increases to make the pressures before and after the poppet equal. Then the relief valve operates
at the specified set pressure.
Poppet
Shockless piston
R35Z72SM07
Θ
Θ
(2)
Содержание R35Z-7
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 9...
Страница 143: ...4 10 MEMORANDUM...
Страница 179: ...4 45 No of pin Receptacle connector Female Plug connector Male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13...
Страница 337: ...7 77 Take out ball bearing 3 from shaft 2 Tools required Ball bearing disassembly jig S 8 Completed 31 32 2 3 R35Z77TM32...
Страница 357: ...7 97 Remove lock nut 24 and then boot 27 16 RE18 140 7 RE19 140 7 25038RL02 4...
Страница 368: ...7 108 3 13 12 Install cover 3 to hub and tighten bolts 12 5 R35Z77TJ04...