5-7
ͽ
Replenish
specified oil to
the standard
level.
Clean oil cooler.
Secure air
circulation route.
Adjust belt
tension or
replace belt.
Readjust set
pressure.
Reduce load.
YES
NO
Is hydraulic oil
volume proper?
Is not oil cooler
clogged and is
anything blocking
air circulation?
Is main relief
valve used very
often?
Is not the set
pressure of main
relief, relief and
travel relief valve
lower than the
standard level?
Is fan belt
tension proper?
ͽ
YES
NO
YES
YES
YES
YES
NO
NO
NO
Drop hydraulic oil
sample on hot
plate and check if
foams come up.
Water is mixed.
Air is intruded.
Put hydraulic oil
still, separate
water and
dispose it or
replace hydraulic
oil.
Check suction
line and return
line and eliminate
the air intruding
source.
3
3. HYDRAULIC SYSTEM
HYDRAULIC OIL IS CLOUDY
1)
HYDRAULIC OIL TEMPERATURE HAS RISEN ABNORMALLY
2)
Cause
Remedy
Cause
Remedy
Содержание R35Z-7
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 9...
Страница 143: ...4 10 MEMORANDUM...
Страница 179: ...4 45 No of pin Receptacle connector Female Plug connector Male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13...
Страница 337: ...7 77 Take out ball bearing 3 from shaft 2 Tools required Ball bearing disassembly jig S 8 Completed 31 32 2 3 R35Z77TM32...
Страница 357: ...7 97 Remove lock nut 24 and then boot 27 16 RE18 140 7 RE19 140 7 25038RL02 4...
Страница 368: ...7 108 3 13 12 Install cover 3 to hub and tighten bolts 12 5 R35Z77TJ04...