5-31
8. WHEN SAFETY SOLENOID DOES NOT OPERATE
Â
Before disconnecting the connector, always turn the starting switch OFF.
Â
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No.10.
Â
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Hydraulic
malfunction
Defective solenoid
Defective switch
(CS-4)
Disconnect in
wiring harness or
poor contact
between
CN-3(12)-CS-4(2)
Disconnect in
wiring harness or
poor contact
between
CN-3(12)-CN-
68(2)
Disconnection in
Check hydraulic
system
Replace
Repair or replace
Repair or replace
(After clean)
Repair or replace
(After clean)
Replace
Check voltage
between CN-68
(1) - CN-68(2)
YES
YES
YES
YES
NO
NO
NO
NO
Safety lever : OFF
Starting switch : ON
Voltage : 10~12.5V
NO
Check operation
of solenoid
Safety lever : ON-OFF
Starting switch : ON
Voltage : 10~12.5V
Disconnect CN-5
Starting switch : ON
Voltage : 10~12.5V
Disconnect CN-5
Starting switch : ON
Voltage : 10~12.5V
Safety state
Check voltage
between CN-68
(2) with chassis
Check voltage
between CS-4
(2) and chassis
Check voltage
between CN-3
(12) and chassis
YES
2
1
12
CN-3
CN-68
CS-4
NO.10
1
2
SAFETY SOLENOID
SAFETY SWITCH
FUSE
11
13
CN-6
R35Z75TS17
Содержание R35Z-7
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 9...
Страница 143: ...4 10 MEMORANDUM...
Страница 179: ...4 45 No of pin Receptacle connector Female Plug connector Male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13...
Страница 337: ...7 77 Take out ball bearing 3 from shaft 2 Tools required Ball bearing disassembly jig S 8 Completed 31 32 2 3 R35Z77TM32...
Страница 357: ...7 97 Remove lock nut 24 and then boot 27 16 RE18 140 7 RE19 140 7 25038RL02 4...
Страница 368: ...7 108 3 13 12 Install cover 3 to hub and tighten bolts 12 5 R35Z77TJ04...