5-25
2. BATTERY CHARGING WARNING LAMP LIGHTS UP(Starting switch : ON)
Â
Before disconnecting the connector, always turn the starting switch OFF.
Â
Before carrying out below procedure, check all the related connectors are properly inserted.
Â
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Defective cluster
Disconnection in
wiring harness or
poor contact
between CN-56(3)
-CN2(13)
Disconnection in
wiring harness or
poor contact
between
CN-2(13)-alternator
terminal "1"
Defective alternator
Replace
Repair or replace
(After clean)
Repair or replace
(After clean)
Replace
YES
YES
YES
NO
NO
NO
CLUSTER
CN-56
10 ~ 12.5V
YES
Check voltage
NO
0V
3
CN-2
13
ALTERNATOR
CN-74
3
2
1
U
3
~
G
L
P
I
B+
Voltage : 10~12.5V
Engine : Running
Check voltage
between alternator
terminal "1" and
chassis
Check voltage
between CN-2
(13) and chassis
Check voltage
between CN-56
(3) and chassis
R35Z75TS11
Содержание R35Z-7
Страница 11: ...SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 9...
Страница 143: ...4 10 MEMORANDUM...
Страница 179: ...4 45 No of pin Receptacle connector Female Plug connector Male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13...
Страница 337: ...7 77 Take out ball bearing 3 from shaft 2 Tools required Ball bearing disassembly jig S 8 Completed 31 32 2 3 R35Z77TM32...
Страница 357: ...7 97 Remove lock nut 24 and then boot 27 16 RE18 140 7 RE19 140 7 25038RL02 4...
Страница 368: ...7 108 3 13 12 Install cover 3 to hub and tighten bolts 12 5 R35Z77TJ04...