7.4 Connection of the level sensor
of the permeate collection tank
If using the ROL unit with a storage tank +
booster pump,
»
connect the high level signal to ter-
minals 22 - 23, and the low level
signal to terminals 33 - 34.
The high level signal can be enabled in the
menu "5 HIGH LEVEL".
The low level signal can be enabled in the
menu "4 LOW LEVEL".
The permeate pressure switch already sup-
plied does not need to be disconnected, as
this does not interfere with the operating logic
of the float.
7.5 Inputs and outputs of the
main board
Contatto allarme
NO
NC
C
19 20 21
Contatto ON/OFF
Segnale di
alto livello
Segnale di
basso livello
37 38
1
2
3
4
clamp
describtion
WL-ROL
1[L] - 2[earth] - 3[N]
230-V 50/60 Hz-Input for system power supply
x
4[L] - 5[earth] - 6[N]
230-V-Output for pump supply
x
7[L] - 8[earth] - 9[N]
230-V-Output for dosing pump
x
10[L] - 11[earth] - 12[N]
230-V-Output for inlet valve
x
13[L] - 14[earth] - 15[N]
230-V-Output for flush valve
x
19[NO] - 20[C] - 21[NC]
alarm aoutput optional
x
22[C] - 23[IN]
input pressure switch Feed water connection / Max pressure
x
24[C] - 25[IN]
input high pressure switch pump pressure
x
26[C] - 27[IN]
input pump motor protection
?
28[C] - 29[IN]
input alarm dosing pump
x
30[schielded] - 31 - 32
conductivity sensor feed water
x
33[C] - 34[IN]
input pressure switch Feed water connection / Min pressure
x
35[C] - 36[IN]
input low pressure switch
x
37[C] - 38[IN]
input Remote-On/Off optional
x
39[C] - 40[IN]
input softening filter
x
41[shielded] - 42 - 43
conductivity sensor row water
x
1 level switch high
2 level switch low
3 alarm exits
4 contact ON / OFF
Содержание WL-ROL 160-1200 Series
Страница 1: ...FlexLine Reverse osmosis plants MANUAL WLROL EN E 8881184 WLROL ENj WL ROL 160 1200...
Страница 62: ...Page 62...
Страница 65: ...Page 65 13 Declaration of Conformity...
Страница 66: ...Page 66...
Страница 72: ...Page 72 This page intentionally left blank...
Страница 73: ...SPA Page 73 This page intentionally left blank...