![HygroMatik WL-ROL 160-1200 Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hygromatik/wl-rol-160-1200-series/wl-rol-160-1200-series_manual_2192888022.webp)
Page 22
5.2.7 Installation of the uv quartz
lamp
Danger from uv radiation
UV radiation is harmful to the skin and eyes:
disconnect power to the UV lamp before per-
forming any operations.
The UV lamp and the quartz are very fragile.
Pay extra care when performing the following
operations to fit and/or remove the lamp and
the quartz:
»
Open the rubber cap (A) and
unscrew the plug (B).
»
Slide the lamp (D) approximately fi
ve centimetres out of the chamber
(G)
»
Securely holding the end of the lamp
(D),
»
carefully remove the fourpin lamp
connector (C) from the open end of
the lamp.
»
Carefully remove the lamp (D) from
the chamber (F).
»
Then unscrew the other end of the
UV lamp to access to O-ring on the
quartz tube.
»
Carefully remove the O-rings (E)
from both ends of the quartz tube
(F).
A
B
C
D E
F
G