8.8
Cleaning Blow-Down Pump
Removal
»
Remove the steam cylinder as described above in sec-
tion “Removing and Cleaning the Steam Cylinder -
Removal.”
»
Detach electrical connector from the pump (10).
»
Detach union adapter (E) from the pump.
»
Remove cap nuts (G) and take the pump out of the cyl-
inder base (11).
»
Open pump (bayonet lock).
»
Remove all residue from the drain hoses and pump
(possibly replace o-ring (A)).
»
Assemble pump.
»
Moisten o-ring (C) and place in the side connection of
the base.
»
Push pump into the base and secure tightly with cap
nuts (G).
»
Moisten o-ring (D) and place on the side connection of
the pump.
»
Slide union adapter (E) over the side connection of the
pump.
»
Connect electrical connector to the pump (polarity not
specified).
»
Open water supply.
»
Switch on unit and check for leaks after 15-30 minutes
of operation.
If leakage occurs, switch off power supply and repair the leaks,
following safety instructions for work on live components!