background image

InstructIons For: 

INDUSTRIAL DEHUMIDIFIER 70

LTR

model no:

 SDH70

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

1.  SAFETY

1.1. 

ELECTRICAL SAFETY

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 

device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected 

by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1. the 

Electricity at Work Act 1989

 requires that all portable electrical appliances, if used on business premises, are tested by a  

qualified electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2. the 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those 

appliances and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. 

ensure that the insulation on all cables and on the appliance is safe before connecting it to the  

power supply. see 1.1.1. and 1.1.2. and use a Portable Appliance tester.

1.1.4. 

ensure that cables are always protected against short circuit and overload.

1.1.5. 

regularly inspect power supply cables and plugs for wear or damage and check all 

connections to ensure that none is loose.

1.1.6. 

Important:

 ensure that the voltage marked on the appliance matches the power supply 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

item repaired or replaced by a qualified electrician. When a Bs 1363/A uK 3 pin plug is 

damaged, cut the cable just above the plug and 

dispose of the plug safely

Fit a new plug according to the following instructions (uK only).

a)

Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b)

Connect the BROWN live wire to the live terminal ‘L’.

c)

Connect the BLUE neutral wire to the neutral terminal ‘N’.

d)

After wiring, check that there are no bare wires, that all wires have been correctly

connected, that the cable outer insulation extends beyond the cable restraint and

that the restraint is tight.

 

double insulated products, which are always marked with this symbol     , are fitted with live (brown) and neutral (blue) wires only. 

 

to rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13amps are supplied without a plug. In this case you must contact a qualified electrician to 

ensure that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and 

socket with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance 

plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that    

the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the 

use of 2.5mm² section cable. If an extension reel is to be used outdoors, ensure it is marked for outdoor use.

RECOMMENDED

 FUSE RATING: 13AMP

refer to the

 instruction manual

1.2. 

GENERAL SAFETY

 

check that the dehumidifier is in sound condition and good working order. 

Take immediate action to repair or replace damaged 

parts.

use recommended parts only.

 Unauthorised parts may be dangerous and will invalidate the warranty.

 

DO NOT

 stand or place any object less than 10cm from the front or rear of the unit.

 

DO NOT

 obstruct the air intakes or outlets of the dehumidifier.

 

DO NOT 

place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

DO NOT

 operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

DO NOT 

switch the dehumidifier off by disconnecting it from the mains. 

ALWAYS 

switch to the “oFF” position first.

 

DO NOT 

remove the float lever from the water collection tank.

 

DO NOT 

connect or disconnect the plug from the mains with wet hands.

 

Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

Place the dehumidifier on a level and stable surface.

 

DO NOT

 use the dehumidifier at ambient temperatures below 5°c.

 

DO NOT

 use the dehumidifier outside.

 sdH70    Issue: 1 - 26/11/14

Original Language Version

 © Jack sealey limited

Summary of Contents for SDH70

Page 1: ...or connectors Immediately have any faulty item repaired or replaced by a qualified electrician When a BS 1363 A UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plug according to the following instructions UK only a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE n...

Page 2: ...enses on the cooling coils falling as droplets into a drip tray and internal or external water tank Efficiency of the dehumidifier is influenced by the air outside the room For operating efficiently avoid opening and closing the windows and doors For best performance operate the dehumidifier within the usable operating temperature 4 1 Operation 4 1 1 Plug the unit in to the mains socket a beep wil...

Page 3: ...ntil the water collection tank has been emptied 4 3 1 Open the dehumidifier door and remove the hose from the water collection tank Then remove the tank fig 3 4 3 2 Hold the tank by the handle and carry it carefully to an emptying point 4 3 3 Empty the water out of the tank 4 3 4 Replace the tank in the dehumidifier making sure it is properly back in place the unit will not restart if it is not fi...

Page 4: ...et at the top of the door and then locate the lower section into the lower bracket 5 1 6 Close the door of the dehumidifier 5 2 Storage 5 2 1 Unplug the unit bundle the power cord and hang the bundled cord at the back of the unit 5 2 2 Remove the water collection tank and empty the water out of it Wash the inside of the tank with clean water DO NOT remove the float lever from the tank Wipe off the...

Reviews: