Page 52
8.6
Unlocking of a Released Thermo Sensor
(for heater element)
If a thermo sensor (for heater element) has released due to a too
high temperature the red release button (P) is some millimetres
above the level of the top of its holder. After the system has
cooled down the release button (P) can be unlocked by pressing
it down a few millimetres.
8.7
Removing Inlet Solenoid Valve and Clean-
ing Fine Mesh Filter
Removal
»
Remove the steam cylinder as described above in sec-
tion “Removing and Cleaning the Steam Cylinder -
Removal.”
»
Seal off water supply and remove screw joint from fresh
water connection.
»
Detach connector hose from base.
»
Remove electrical connectors from solenoid.
»
Remove solenoid valve mounting screws.
»
Take the solenoid valve out of hole.
Cleaning
»
Remove fine mesh filter from the solenoid valve and
clean.
Installation
»
Place solenoid valve with seal in the hole in the unit
cabinet.
»
Secure solenoid valve tightly with screws.
»
Attach fresh water connection.
»
Connect elecrical cable to the solenoid valve.
»
Attach connector hose to the base by using clamps.
»
Install cylinder as described above in section “Cleaning
Steam Cylinder - Assembly”.
»
Open water supply.
»
Switch on unit and check for leakage after 15-30 min-
utes of operation.
If leakage occurs, switch off power supply and repair the leaks,
following safety instructions for work on live components!