background image

Model 850 Steam Humidifier Fan Pack

Table oF ConTenTS

Safety Cautions

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

Materials list

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

operation

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Specifications & Dimensions

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Installation Instructions

 

Location  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

  Mount Housing   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
  Hose Connections   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
  Electrical Wiring   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
  Grille Installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Start-up Procedure

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

Maintenance

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

Troubleshooting Guide

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

Service Parts

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

limited Warranty

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11

ReaD anD SaVe THeSe InSTRUCTIonS

Model 850 Steam Humidifier Fan Pack

Installation & Maintenance Instructions

Summary of Contents for 850

Page 1: ...ions 3 Installation Instructions Location 4 Mount Housing 6 Hose Connections 6 Electrical Wiring 7 Grille Installation 7 Start up Procedure 8 Maintenance 8 Troubleshooting Guide 9 Service Parts 10 Limited Warranty 11 READ AND SAVE THESE INSTRUCTIONS Model 850 Steam Humidifier Fan Pack Installation Maintenance Instructions ...

Page 2: ...Disconnect electrical power before installing supply wiring or performing service or maintenance procedures on any part of the humidification system Failure to disconnect electrical power could result in fire electrical shock and other hazardous conditions These hazardous conditions could cause property damage personal injury or death Contact with energized circuits can cause property damage sever...

Page 3: ...umidity the Model 800 Residential Steam Humidifier provides power to the Model 850 Fan Pack The Model 850 blower distributes the steam to the room When the call for humidity ends and the humidifier stops producing steam the Model 850 Fan Pack will continue to operate for 2 minutes to distribute the remaining steam before de activating Operation Figure 1 Dimensions of the Model 850 17 1 16 6 7 8 6 ...

Page 4: ...midifier When the humidifier is wired to 120 volts the fan pack will deliver 11 5 gpd with up to 2 feet of hose or insulated pipe Each additional 2 feet of hose or pipe will reduce output by approximately 1 gpd Humidity behaves like a gas and under ideal conditions will expand to fill the space However air movement due to drafts or as a result of temperature stratification may cause uneven distrib...

Page 5: ...5 will reduce the amount of unobstructed space required to absorb discharged steam but the distances provided are recommended minimums NOTE If operating on 240V condensation running through the steam hose back into the canister may cause a gurgling noise Install Tee Trap 4028 as shown in Figure 5 to divert condensation to drain to eliminate gurgling noise INSTALLATION INSTRUCTIONS continued 1 1 2 ...

Page 6: ... with the Model 800 to the Model 850 and use hose clamp provided with Model 800 to secure See Figure 7 If more than 6 feet is required use insulated hard pipe as shown in Figure 3 See Model 800 manual for the affect on capacity Connect 3 8 ID condensate tubing to the Model 850 and use wire tie to secure See Figure 7 To create a trap make a 6 loop in the condensate hose See Figure 2 NOTE The 6 loop...

Page 7: ... discharge but at least ten feet away Wire the Manual Humidistat to the Model 800 using standard 24 volt thermostat wire See Figure 8 Disconnect all power to Model 800 before wiring the Model 850 terminals to the FAN PACK terminals on the Model 800 Use standard 24 volt thermostat wire See Figure 8 Figure 8 Wiring Diagram for Manual Humidistat and Model 850 90 1816 FAN PACK HUMIDISTAT TRANSFORMER 2...

Page 8: ...or humidification Check drain steam and condensate hoses for kinks blockages leaks or cracks Replace if necessary Ensure steam outlet of the fan pack is not blocked Maintenance Verify that there are no leaks at steam hose connections The Model 850 will operate on a call for humidity and the production of steam by the Model 800 Residential Steam Humidifier When the call for humidity is de activated...

Page 9: ...heck location of humidistat Circuit board output Confirm 24 VAC output from Model 800 FAN PACK terminals during a call for humidity Motor failure Replace fan motor Noise Fan noise Check for obstructions or damage to fan Gurgling Add a drip tee and trap PN 4028 to the steam line as close to the Model 800 as possible to divert condensation to drain See Figure 5 If a problem arises with the Aprilaire...

Page 10: ...SERVICE PARTS Part No Description 65 Digital Manual Humidistat 4028 Tee Trap 4851 Blower Activation Relay 4997 Condensate Tubing with Wire Ties 4998 Grille 4999 Fan 5404 Transformer 20VA 10 ...

Page 11: ...R PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED ...

Page 12: ...P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilairepartners com 10010006 4 13 B2205862B Printed in U S A 2013 Aprilaire A division of Research Products Corporation ...

Page 13: ......

Page 14: ......

Reviews: