69/98
Last change 10/2018 E-P | Subject to technical modifications
1. Malfunction of micro processor control
Different modes are monitored during operation and regeneration of the softener. If during operation
of the central control valve faults should become evident, the failure records are shown in the LCD
display and the failure contact and failure signal light switched.
Information regarding possible failure records see chapter
V
/ point 6.
2. No water supply
No. Inspection
Result
Action
1.
Open sample cock before
softener
No water
Open stop valves before
softener
Water flows
Proceed with 2
2.
Open sample cock in soft water
line
Water flows
Open service valve
leading to consumer
No water
Proceed with 3
3.
Check power supply as far as
control system
Interrupted power supply
Provide power supply
Power supply available
Proceed with 4
4.
Force regeneration and check
whether or not drive motor is
running (possibly with 2
– 6
minutes delay)
Drive motor starts
Regeneration interrupted
before switch-over was
finished
Drive motor does not
start
Faulty control;
Call service!
6.
Force regeneration in order to
change to second vessel
Water flows
Nozzles in exchanger are
possibly blocked.
Proceed with 7.
No water flows despite
Faulty control head;
Call service!
7.
After regeneration sequence has
been finished, switch-over to
regenerated vessel
No water does flow
Call service!
Water flows
Carry out maintenance
and arrange for system
to be inspected.
Содержание HYDROION VAD 125-CS 1
Страница 18: ...18 98 Last change 10 2018 E P Subject to technical modifications 2 4 Pressure loss curve...
Страница 80: ...80 98 Last change 10 2018 E P Subject to technical modifications Appendices 1 Installation schematic softener...
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......