AP-DWS1000 Drinking Water Appliance Owner’s Manual
Installation Precautions
6888931 0701
Installation and
Operating Instructions
•
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
•
Installation must comply with state and local
plumbing codes.
•
Systems certified for cyst reduction may be
used on disinfected water that may contain
filterable cysts.
•
System must be protected from freezing. Drain
filter when room temperature drops below
40°F (4.4°C).
•
Do not install on line pressure above 125 psi
(862 kPa).
•
Do not install on hot water line. Maximum
temperature allowed is 100°F (38°C).
•
The filter must be installed with the inlet and
outlet ports as labeled. Make sure not to
reverse connections.
•
Do not use wicking or sealer for fitting connections
into head of filter. Use Teflon
®
tape for connections.
•
Do not use torch or other high temperature
sources near filter or plastic cartridge.
•
Do not install near electric wires or water pipes
which will be in the path of drill when selecting
the position to mount bracket.
•
Do not install in direct sunlight.
•
Allow a minimum of 2” (5cm) clear space
under filter to facilitate cartridge change.
•
Mount filter in such a position as to prevent it
from being struck by other items.