Last change 10/2018 E-P | Subject to technical modifications
3.2 Alarm records
Below is a survey of possible alarm or warning records:
Record
Failure
Reason / background
Action
Pre-warn
Maintenance
necessary
Maintenance interval
soon running out
Arrange for maintenance soon and
confirm in menu
Alarm
Maintenance
necessary
Maintenance interval ran
out
Arrange for immediate maintenance
and confirm in menu
Pre-warn
Power failure
Separated for mains of
power failure
Acknowledge failure
Pre-warn
Brine lack
No saturated brine in
brine tank
Add salt into brine tank
Alarm
Brine lack
No saturated brine in
brine tank and a
regeneration is due to be
released
Add salt into brine tank
Pre-warn
Chlorinator
Blockage
The actual current is
outside the tolerance for
nominal current
Deposit on chlorine electrode
clean or replace
Pre-warn
Chlorinator
Blockage
The duration of the
chlorine production is
higher than the brine
intake period
Check brine intake period and
chlorine production duration and
adjust if necessary. Alarm delay set
too low
Alarm
Chlorinator
Saturation
The required current
cannot be achieved
even with quite high
voltage
Too low brine saturation
add salt tablets
possibly check hydraulics of brine
intake
Alarm
Chlorinator
Short circuit
Hardware error or false
terminal charge
Check installation
Alarm
head 1/2 time
exceeded
Move time of valve
motor too long
Check plug connections at valve and
terminals in the controller
Alarm
head ½ time
increments
Piston position not
reached
Check plug connections at valve and
terminals in the controller
Alarm
head 1/2 stdby current
Hardware error
Check pcb’s and terminals
Alarm
head 1/2 tract. current
Hardware error
Check pcb’s and terminals
Alarm
head 1/2 high current
Hardware error
Check pcb’s and terminals
Alarm
head 1/2 low voltage
Hardware error
Check pcb’s and terminals
Alarm
head 1/2 high voltage
Hardware error
Check pcb’s and terminals
Alam
Alternator low current
Hardware error
Check pcb’s and terminals
Alarm
Alternator high current
Hardware error
Check pcb’s and terminals
Alarm
Alternator time
exceeded
Move time of valve
motor too long
Check plug and socket contacts on
valve and terminal clamps on the
control unit
Alarm
Alternator low voltage
Hardware error
Check pcb’s and terminals
Alarm
flow fallen below
Too less flow
Increase removal
Alarm
flow exceeded
Too high flow
Reduce removal
Alarm
lack of pressure
Too low input pressure
Check input pressure
Содержание HYDROION VAD 125-CS 1
Страница 18: ...18 98 Last change 10 2018 E P Subject to technical modifications 2 4 Pressure loss curve...
Страница 80: ...80 98 Last change 10 2018 E P Subject to technical modifications Appendices 1 Installation schematic softener...
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......