15/98
Last change 10/2018 E-P | Subject to technical modifications
2. Technical Data
2.1
Technical data
HYDROION® VAS
– CS – A
Systems with full salting
(Type A)
25-CS
1 - A
50-CS
1 - A
75-CS
1 - A
125-CS
1,5 - A
150-CS
1,5 - A
200-CS
1,5 - A
250-CS
2 - A
375-CS
2 - A
600-CS
2 - A
Connection mains / soft water line
DN 25 (1")
DN 40 (1 1/2")
DN 50 (2")
DN 80
Drain line (mind.)
DN 50
DN 50
DN 70
Mains electrical connection
230 V / 50 Hz AC
230 V / 50 Hz AC
230 V / 50 Hz AC
Electrical connection (secondary)
12 V AC
12 V AC
12 V AC
Water temperature (min./max.)
5 °C / 30 °C
5 °C / 30 °C
5 °C / 30 °C
Ambient temperature (min./max.)
5 °C / 40 °C
5 °C / 40 °C
5 °C / 40 °C
Operational pressure
(min./max.)
2)
2 bar / 8 bar
2 bar / 8 bar
2 bar / 8 bar
Performance data
Nominal flow
1)
m³/h
2.5
3.5
4.5
6.5
8.0
10.5
13.5
17.0
24.0
Flow rate at blending
(300 ppm to 60 ppm)
m³/h
3.1
4.4
5.6
8.1
10.0
13.1
16.9
21.3
30.0
Pressure loss at rated flow
1)
bar
0.43
0.66
0.88
0.78
0.65
1.14
1.05
1.34
1.94
Capacity at 300 ppm CaCO
3
1)
m³
5.3
10.8
16.2
27.3
32.2
43.5
54.9
82.8
132.3
Salt consumption
kg
5
10
15
25
30
40
50
75
120
Waste water volume per
regeneration
m³
0.17
0.36
0.55
0.88
1.06
1.40
1.73
2.62
4.20
Volume and weights
Resin vessel volume
Ltr.
38.4
79.5
115
153
277
277
344
473
704
Quantity of resin
Ltr.
25
50
75
125
150
200
250
375
600
Quantity of gravel
kg
4
7
10
17
40
40
40
58
40
Brine tank volume
Ltr.
140
190
340
460
460
670
920
1000
1500
Regeneration salt supply
kg
50
75
125
175
162
250
325
375
525
Operational weight
(complete unit) max.
kg
125
210
325
465
620
740
925
1210
1750
Dimensions
Height (max.)
mm
1235
1530
1600
1600
1700
1700
2000
2200
2220
Ceiling height (min.)
H
mm
1800
1800
1900
1900
2000
2000
2200
2400
2500
Width (max.)
B
mm
910
960
1160
1360
1550
1730
1980
2050
2480
Depth (max.)
T
mm
600
600
725
850
850
1000
1150
1150
1500
Clearance tank/tank (ca.)
A1
mm
510
530
630
760
820
900
1020
1070
1340
Diameter pressure tank
D1
mm
258
310
363
413
555
555
555
635
779
Diameter brine tank
(min. / max.)
D2
mm
460 /
565
460 /
565
594 /
723
703 /
833
703 /
833
847 /
973
997 /
1123
1015 /
1120
1050 /
1150
Height pressure tank
(incl. foot)
H1
mm
897
± 6
1232
± 6
1344
± 6
1341
± 15
1434
± 15
1434
± 15
1721
± 15
1918
± 15
1892
± 15
Height top control valve
H2
mm
1080
1420
1530
1570
1665
1665
1930
2130
2160
Height brine tank
H3
mm
843
1123
1200
1196
1196
1196
1206
1340
1500
Height feed (mains
water) / discharge
(softwater)
H4
mm
960
1295
1400
1430
1520
1520
1810
2010
2040
Control box
(W x H x D)
mm
240 x 170 x 110
Mounting board
(W x H x D)
mm
330 x 200 x 10
1)
Parameters are dependent on operation mode and water input quality.
2)
At operating pressure min. the flow pressure is decisive, at operating pressure max. the static
pressure is decisive
For the use in the field of boiler feed water, preliminary treatment and reverse osmosis a project
planning is always required performed by our Applications engineering department!
Содержание HYDROION VAD 125-CS 1
Страница 18: ...18 98 Last change 10 2018 E P Subject to technical modifications 2 4 Pressure loss curve...
Страница 80: ...80 98 Last change 10 2018 E P Subject to technical modifications Appendices 1 Installation schematic softener...
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......