Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
7.3
The Recipe Editor – Page 2
Pressing the Next button
at the bottom of the screen displays the second page of the
recipe editor which has the Mix Control, Local Auto-Track, Admix and Temperature Correction
Settings.
Figure 36: The recipe editor – page 2
Mix Control
Parameter
Units
Default
Range
Pre-wet Water Control Method
None
Preset
Preset/Auto/Calculation
Pre-wet Moisture Target
%
8
0 – 99.9 %
Control Method
None
Preset
Preset/Auto/Calculation
Moisture Target
%
10
0 – 99.9 %
Plus Tolerance
%
2.75
0 – 99.9 %
Minus Tolerance
%
2.75
0 – 99.9 %
The
Pre-wet Control Method
changes the method that is used to control the pre-wet water
addition. If the method is set to Preset, then a fixed quantity of water is added defined by the
parameter
Pre-wet Water
in the Water Addition section on page 1 of the recipe parameters. If
the method is set to Auto, then the water is added in AUTO Mode to reach the target defined
as
Pre-wet Moisture Target
.
Содержание Hydro-Control VI
Страница 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...