Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
19
3 Operating Temperature
The unit has been designed to work in ambient air temperatures inside the cabinet of 0 – 40 °C
(32 – 104 °F).
Where ambient temperatures vary from this a temperature regulation system may need to be
installed.
4 OPTO modules
The OPTO-22 I/O modules are accessed through the removable panel on the rear of the unit. The
panel is held in place by four captive screws. When the screws are released and the panel is
removed, the OPTO modules can be individually removed and replaced using their individual
retaining screws. All power should be removed, from both the unit and the field wiring, whilst the
cover is not in place.
5 Memory Cards
Note: HC06 v2 utilises an internal SSD hard drive and does not contain removable
memory cards (Figure 5). The SSD hard drive is not removable, therefore, no user
maintenance is possible. Contact [email protected] for assistance in the event of
a failure.
There are two memory card slots and these are accessed by removing the mounting bracket on
the top left corner of the Hydro-Control (as viewed from the rear). Removing the two small screws
opens the access plate over the card sockets (shown in Figure 7).
Figure 7: The memory card access port showing the labels of the cards
As shown in Figure 7, the memory cards are mounted so that the System Card is nearest to the
front of the unit and the Data Card is nearest to the rear. Both cards are clearly labelled. The
System Card is coloured blue and the data card is coloured beige.
The memory cards should always be inserted so that the Hydronix Logo is facing the rear of the
unit. The System Card should never be transferred between units.
If needed the System Card can be replaced with Hydronix Part Number 0176. The Card must be
replaced with the same colour card as the original factory fitted card.
Over time the memory cards can degrade in performance and so the Data Card should be replaced
every five years with Hydronix Part Number 0177.
Use Hydronix original parts to ensure compatibility and continuing reliability of the unit.
Memory
Cards
Содержание Hydro-Control VI
Страница 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...