![Hydronix Hydro-Control VI Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_installation-manual_2192335038.webp)
38
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
System Auto Control Setup
Parameter
Units
Default
Range
Proportional Gain
None
5
-100 – 100
Integral Gain
None
0
-100 – 100
Derivative Gain
None
0
-100 – 100
The
Proportional, Integral
and
Derivative Gain
parameters control the water valves during
AUTO Mode. They compare the current sensor value with the target and generate a control
signal for the speed of water addition (during the process the speed of water addition is
controlled initially by opening the coarse and fine valve fully and, as the error is reduced, by
closing the coarse valve and varying the pulse rate of the fine valve). Optimising these
parameters is described in the Operators Guide in the chapter ‘Using Moisture Control’.
These system parameters can be over-ridden from within each recipe.
System Auto-Track
Parameter
Units
Default
Range
Initial Mix Deviation
%
0.1
0 – 100
Initial Mix Time
Seconds
10
0 – 100
Pre-wet Mix Deviation
%
0.1
0 – 100
Pre-wet Mix Time
Seconds
10
0 – 100
Dry Mix Deviation
%
0.1
0 – 100
Dry Mix Time
Seconds
10
0 – 100
Wet Mix Deviation
%
0.1
0 – 100
Wet Mix Time
Seconds
10
0 – 100
The
Initial Mix Deviation, Initial Mix Time, Pre-wet Mix Deviation, Pre-wet Mix Time, Dry
Mix Deviation
,
Dry Mix Time
,
Wet Mix Deviation
and
Wet Mix Time
parameters are used by
the Auto-Track feature to control when the system finishes the initial, pre-wet, dry and wet mix
phases. During the initial, pre-wet, dry or wet mix phase, if the variation in the sensor value is
less than the specified Mix Deviation for the Mix Time then the mixing phase will continue to
the next phase.
See the section on Auto-Track on page 66 for more details.
These system parameters can be over-ridden from within each recipe.
Содержание Hydro-Control VI
Страница 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Страница 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...