HydraMaster Corporation
Page 4-4 : CTS 330 Owner’s Manual
CTS 330
Hot Carbonating Truckmount System
Blower
Quick Reference List:
Check blower level.
Drain oil.
Fill oil.
Lube blower.
Blower Oil Change
The vacuum blower has grease ports in the front and
one
sight glass
for checking the oil level (
Figure 4-6
). The sight
glass is located in the rear of the blower and can be viewed by
looking at the right side on the rear case of the blower. The
oil level should be checked
daily
to ensure that it reaches
over half the sight glass.
Tools:
11/16 wrench
5/8 wrench
Grease gun
1. Remove the oil drain cap, which is
located on the oil drain hose on the side
of the machine. (
Figure 4-7
).
2. Remove oil fill cap.
3. Fill the blower with 40W non-detergent
oil. After oil begins to flow out of the
oil drain fitting, re-install the caps. This
will
allow air to evacuate from
the system
and give accurate oil
level reading.
Failure to do this step will result in an
insufficient amount of oil in the blower
will lead to damage or failure!
4. Re-install the oil fill plug.
5. Attach grease gun to zerks and pump
grease into the blower until grease flows out of the weep holes.
Figure 4-6
Figure 4-7
Содержание CTS 330
Страница 2: ......
Страница 23: ...Page 1 15 CTS 330 Owner s Manual CTS 330Hot Carbonating Truckmount System Figure 1 4 Hard Water Map...
Страница 93: ...Page 9 5 CTS Owner s Manual CTS 330Hot Carbonating Truckmount System...
Страница 137: ...40 NOTES...
Страница 142: ......
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......