l
zone1: port1 and port3
l
zone2: port1 and port4
l
zone3: port2 and port5
l
zone4: port2 and port6
AS with Two FC HBAs+Three NICs+ Direct Connection
Figure 2-6
shows the cluster networking of AS with two FC HBAs+three NICs+ direct
connection.
Figure 2-6
Cluster networking of AS with two FC HBAs+three NICs+ direct connection
Optical fiber
FC host port
Cluster
node-main
Cluster
node-backup
Heartbeat line
Network cable
Public network
NIC 1 port 1
AS 1
AS 2
FC HBA 2 port 1
FC HBA 3 port 1
NIC 2 port 1
NIC 3 port 1
NIC 4 port 1
NIC 5 port 1
NIC 6 port 1
UltraPath
UltraPath
FC HBA 1 port 1
FC HBA 4 port 1
Controller A
Controller B
S5600 controller subrack (FC host ports)
00 0102 03
00 0102 03 10 1112 13
10 1112 13
IP address of port 1 on NIC 1: 129.20.11.1
Subnet mask: 255.255.224.0
IP address of port 1 on NIC 2: 10.147.0.5
Subnet mask: 255.255.0.0
IP address of port 1 on NIC 3: 10.147.0.15
Subnet mask: 255.255.0.0
IP address of port 1 on NIC 4: 10.147.0.16
Subnet mask: 255.255.0.0
IP address of port 1 on NIC 5: 10.147.0.6
Subnet mask: 255.255.0.0
IP address of port 1 on NIC 6: 129.20.11.2
Subnet mask: 255.255.224.0
OceanStor S5600 Storage System
Initial Configuration Guide
2 Setting Up the Management Environment
Issue 02 (2009-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-13