
GSC53N - GSC57 - ZG47
EN - 88
8.5.
"CURRENT" FUNCTION
This function permits to display in real time the RMS value of AC/DC currents, the peak
and Thdl value (see paragraph 17.11) of the 3 phase currents, the waveform and the
harmonic spectrum of the 3 phase currents.
8.5.1. Symbols
The CURRENT position has three working modes:
METER
WAVE
HARM
These modes will be described in detail in the next paragraphs.
The symbols used are described below:
Symbol
Description
I1, I2, I3
RMS value of the current of phase 1, phase 2, phase 3 respectively
IN
RMS value of the current on the neutral
Ipk1, Ipk2, Ipk3
Peak value of the current of phase 1, phase 2, phase 3 respectively
h01 h49
Harmonic 01 harmonic 49.
ThdI
Total harmonic distortion factor of the current (see paragraph 17.11).
freq
Network frequency
Table 8: symbols used in the position CURRENT
Содержание GSC53N
Страница 1: ...Copyright HT ITALIA 2012 Release EN 1 08 28 02 2012 GSC53N GSC57 ZG47 Instruction Manual...
Страница 2: ......
Страница 151: ......