FC processor failed to re-initialize in response
to an IOCTL disable request.
Error
FC
#%d: QLIoctlDisable: Re-
initialize adapter failed
106593
FC processor reported a link down condition.
Error
FC
#%d: QLIsrEventHandler:
Link down (%x)
106803
FC processor reported an unexpected asyn-
chronous event. The mailbox registers provide
status, event code, and data related to the
event.
Error
FC
#%d: QLIsrEventHandler:
Unexpected async event
(%x), MB1=%x, MB2=%x,
MB3=%x, MB4=%x, MB5=%x,
MB6=%x, MB7=%x
106813
FC controller reported an invalid Entry Status
%x, type %x.
Error
FC
#%d: QLProcessRespon-
seQueue: Invalid
EntryStatus %x, type %x
106847
FC controller failed to provide a heartbeat.
Error
FC
#%d: QLTimer: Heartbeat
failed
106851
Driver has determined that the FC link is unre-
liable and unusable due to the number of er-
rors encountered. The link has been taken
down.
Error
FC
#%d: QLTimer: Link error
count (0x%x) exceeded,
link down
106853
FC processor was unable to obtain the number
of loop IDs required. This failure occurs only
when the FC processor is running multi-ID
firmware.
Error
FC
#%d: QLReserveLoopId: out
of loop Ids
106912
Driver was unable to re-establish connection
to the target within the timeout and retry
counts, and is therefore marking it
offline
.
Error
FC
#%d: QLMarkDeviceOffline:
Device Id: %x marked off-
line, cLinkDownTimeout =
%x, cPortDownRetryCount=
%x
106928
FC processor is unable to log into the FC fabric
name server.
Error
FC
#%d: QLSnsGetAllNext:
Name server login FAILED
%x
106948
Driver’s host (initiator) database is full.
Error
FC
#%d: QLUpdateDeviceData:
out of slots in host
database
107029
Driver’s target database is full.
Error
FC
#%d: QLUpdateDeviceData:
out of slots in target
database
107030
Driver’s host (initiator) database is full. Maxim-
um hosts is 64.
Error
FC
#%d: QLUpdateDeviceData-
base 0x%x: GET_ID failed
%x
107041
Drivers host (initiator) database is full.
Error
FC
#%d: QLUpdateDeviceDatabase
0x%x: out of
slots in host
database
107056
Driver was unable to re-establish connection
to the target within the timeout and retry
counts, and is therefore marking it
offline
.
Error
FC
#%d: QLUpdatePort 0x%x:
out of slots in host
database
107078
Log messageslog messages
342
Содержание Storageworks 8100 - enterprise virtual array
Страница 20: ...20 ...
Страница 30: ...MPX200 Multifunction Router overview 30 ...
Страница 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Страница 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Страница 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Страница 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Страница 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Страница 222: ...Controller Id WWPN PortId Path Status 0 20 78 00 c0 ff d5 92 e5 02 04 00 Current Optimized Offline Data Migration 222 ...
Страница 248: ...Offline Data Migration 248 ...
Страница 258: ...Diagnostics and troubleshooting 258 ...
Страница 306: ...Command referencecommand reference 306 ...
Страница 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Страница 368: ...Saving and restoring the MPX200 configuration 368 ...
Страница 402: ...Data migration best practices 402 ...
Страница 408: ...408 ...