Diagnostic and system error messages reference guide
90
Fabric OS 3.x Document Addendum
Severity
CRITICAL
DIAG-ERRSTAT (2LONG)
Message
Probable Cause
The Port Error Statistics counter is nonzero, which means that a
Frame too long
error
was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP.
It can also indicate more serious problems in the motherboard or ASIC. This message is
generated by the
portloopbacktest
or
spinsilk
command. The
error code
value
is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-ERRSTAT (2LONG), 1, <test name>, pass <number>,
Pt<port information> FrmTooLong Error Counter is <number> sb 0,
Err# <error code>
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...