Diagnostic and system error messages reference guide
102
Fabric OS 3.x Document Addendum
Severity
CRITICAL
DIAG-PORTABSENT
Message
Probable Cause
The port is not present. This can be caused by a faulty cable or deteriorated SFP. It can also
indicate more serious problems in the motherboard or ASIC. This message is generated by the
portloopbacktest
or
spinsilk
command. The
error code
value is for internal use
only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-PORTDIED
Message
Probable Cause
The port was in loopback mode and then went inactive. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the
crossporttest
,
portloopbacktest
, or
spinsilk
command. The
error code
value is for internal use only.
<timestamp>
CRITICAL DIAG-PORTABSENT, 1, <test name>, pass <number>,
Pt<port info> is not present, cannot run test,
Err# <error code>
<timestamp>
CRITICAL DIAG-PORTDIED, 1, DIAG-PORTDIED
<test name>, pass <number>,
Pt<port info><speed> Was Active but Went Inactive (Offline),
Err# <error code>
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...