Fabric OS reference guide
207
Fabric OS 3.x Document Addendum
Example
To display an E_Port:
See Also
authutil
portcfglongdistance
portstatsshow
switchshow
sw5:admin>
portShow 3
portName:
portHealth: HEALTHY
Authentication: type DHCHAP, hash SHA1, group 0
portFlags: 0x28057 PRESENT ACTIVE E_PORT G_PORT U_PORT LOGIN LED
portType: 3.1
portState: 1Online
portPhys: 6In_Sync
portScn: 5E_Port
portRegs: 0x80000000
portData: 0x10fa9ef0
portId: 011300
portWwn: 20:03:00:60:69:00:00:10
portWwn of device(s) connected: 20:00:00:60:69:50:03:83
Distance: normal
Speed:2Gbps
Interrupts: 15502 Link_failure: 0 Frjt: 0
Unknown: 0 Loss_of_sync: 2 Fbsy: 0
Lli: 12 Loss_of_sig: 1
Proc_rqrd: 15484 Protocol_err: 0
Timed_out: 0 Invalid_word: 0
Rx_flushed: 0 Invalid_crc: 0
Tx_unavail: 0 Delim_err: 0
Free_buffer: 0 Address_err: 0
Overrun: 1 Lr_in: 3
Suspended: 0 Lr_out: 1
Parity_err: 0 Ols_in: 1
2ndary_parity_err: 1 Ols_out: 3