Diagnostic and system error messages reference guide
113
Fabric OS 3.x Document Addendum
Recommended Action
If the reconfiguration was unplanned, check for problems with the specified port. Some
troubleshooting tasks consist of:
■
Verifying that the port was not disabled, using the
portshow
command
■
Verifying that the port is cabled correctly
■
Verifying that the SFP has not deteriorated
Refer to the Fibre Channel Standard FC-SW3, Chapters 6 and 7, for more information on
fabric initialization.
Severity
INFO
MS-CT_REQUEST_FAIL
Message
Probable Cause
The management server (MS) received an invalid common transport (CT) response from
switch
domain
. MS expects either a CT accept IU or a reject IU; the management server
received neither response, which violates the Fibre Channel Generic Services (FS-GS)
specification.
Recommended Action
Check the integrity of the FC switch at the specified domain. It is not sending correct MS
information as defined by the FC-GS standard.
Severity
WARNING
D-list conflict
The principal switch received a domain list that contains
more domains than what the principal switch has already
assigned.
<timestamp>
WARNING MS-CT_REQUEST_FAIL, 3, MS CT request failure for domain <domain>
(cmd=0xF004, code=0xFFFFFFFF)
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...