Diagnostic and system error messages reference guide
84
Fabric OS 3.x Document Addendum
DIAG-CMBISRF
Message
Probable Cause
The ASIC central memory SRAMs did not complete the BISR within the timeout period. This
usually indicates an ASIC failure. This message is generated by the
centralmemorytest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMBISRTO
Message
Probable Cause
The ASIC central memory SRAMs did not complete the BISR within the timeout period. This
usually indicates an ASIC failure. This message is generated by the
centralmemorytest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
<timestamp>
CRITICAL DIAG-CMBISRF, 1, <test name>, pass <number>,
Pt<port information> BISR,BIST Self-Test Failed,
RAMs fail bitmap: is 0x<actual value> sb 0x<expected value> er 0x<err
value>,
Err# <error code>
<timestamp>
CRITICAL DIAG-CMBISRTO, 1, <test name>, pass <number>,
Pt<port information> BISR,BIST Timed Out,
RAMs done bitmap: is 0x<actual value> sb 0x<expected value> er 0x<err
value>,
Err# <error code>
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...