Diagnostic and system error messages reference guide
81
Fabric OS 3.x Document Addendum
DIAG-CAMFLTR
Message
Probable Cause
The ASIC internal logic failed. This usually indicates an ASIC failure. This message is
generated by the
filtertest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CAMINIT
Message
Probable Cause
A port failed to initialize due to one of the following reasons:
■
Switch is not disabled.
■
Diagnostic queue is absent.
■
Malloc failed.
■
Chip is not present.
■
Port is not in loopback mode.
■
Port is not active.
■
There was a software operational setup error or motherboard failure.
■
There occurred a retry, reboot, or replacement of motherboard assembly.
<timestamp>
CRITICAL DIAG-CAMFLTR, 1, <test name>, pass <number>,
Pt<port info> Failed Filter Test (test=<test number>, match:<cam type>),
filter <hit | nhit> on <actual filter number>(sb:<expected filter number>)
action type: <actual action>(sb:<expected action>)
Err# <error code>
<timestamp>
CRITICAL DIAG-CAMINIT, 1, <test name>, pass <number>,
Pt<port information> Failed to Init: <additional message>,
Err# <error code>
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...