Diagnostic and system error messages reference guide
116
Fabric OS 3.x Document Addendum
SEC-INITERR
Message
Probable Cause
The
secmodeenable
command failed because the switch does not support secure mode.
Recommended Action
Check that all conditions required for secure mode are installed on the switch. Correct any
missing requirements, such as a missing zoning license, RCS capability, or the PID mode on
the switch. Refer to the HP StorageWorks Secure Fabric OS Version 1.0 User Guide for more
information on secure mode requirements.
Severity
ERROR
SEC-PIDCHGERR, PID Change failed: Change Area failed
Message
Probable Cause
Either the defined or active policy could not be updated. If the policy database is very large, it
might not be able to change the area because the new policy database exceeds the maximum
size. This message can also be caused when the switch is short of memory. The status values
can be
defined
,
active
, or both. A negative value means that a policy set was failed by
the daemon.
Recommended Action
Reduce the size of the policy database.
Severity
ERROR
<timestamp>
ERROR SEC-INITERR, 2, Initialization failed: Switch is not security
capable. Disabling Security mode.
<timestamp>
ERROR SEC-PIDCHGERR, 2, PID Change failed: Change Area failed. <defined
status> <active status>
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...