Diagnostic and system error messages reference guide
111
Fabric OS 3.x Document Addendum
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
■
For the SAN Switch 2/16, replace the motherboard FRU.
■
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-XMIT
Message
Probable Cause
The port failed to transmit a frame. This usually indicates an ASIC failure. This message is
generated by the
camtest
,
portloopbacktest
, and
spinsilk
commands. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
<timestamp>
CRITICAL DIAG-XMIT, 1, <test name>, pass <number>,
Pt<port info> Cannot Transmit Frame: <ftx function> returns <error>,
Err# <error code>