Fabric Watch User Guide
243
Fabric OS 3.x Document Addendum
Figure 34: Port Detail Report
Table 22
lists and describes each category in the port detail report.
Table 22: Port Detail Report Columns
>
fwportdetailshow
Port Detail Report Report time: 01/16/2004 11:12:28 AM
Switch Name: swd21
IP address: 10.32.243.21
Port Exception report [by All]
--------Port-Errors------------ -----SFP-Errors----
Port# Type State Dur(H:M) LFA LSY LSI PER INW CRC PSC STM SRX STX SCU SV0
--------------------------------------------------------------------------------
000 E HEALTHY 062:11 - - - - - - -
- - - -
-
001 L HEALTHY 062:11 - - - - - - -
- - - -
-
002 E
MARGINAL 062:11 - - - - - - -
X
- - -
-
003 U OFFLINE 062:11 - - - - - - -
- - - -
-
004 U OFFLINE 062:11 - - - - - - -
- - - -
-
005 E MARGINAL 062:11 - - - X
- - -
- - - -
-
006 U OFFLINE 062:11 - - - - - - -
- - - -
-
007 U OFFLINE 062:11 - - - - - - -
- - - -
-
008 U OFFLINE 062:11 - - - - - - -
- - - -
-
009 U OFFLINE 062:11 - - - - - - -
- - - -
-
010 U OFFLINE 062:11 - - - - - - -
- - - -
-
011 U OFFLINE 062:11 - - - - - - -
- - - -
-
012 U OFFLINE 062:11 - - - - - - -
- - - -
-
013 U OFFLINE 062:11 - - - - - - -
- - - -
-
014 U OFFLINE 062:11 - - - - - - -
- - - -
-
015 U OFFLINE 062:11 - - - - - - -
- - - -
-
016 U OFFLINE 062:11 - - - - - - -
- - - -
-
Report Item
Description
LFA
Link loss: the number of link loss occurrences out of range for the time
period
LSY
Sync loss: the number of sync loss occurrences out of range for the time
period
LSI
Signal loss: the number of signal loss occurrences out of range for the time
period
PER
Protocol error: the number of protocol errors out of range for the time
period
INW
Invalid word: The number of invalid words out of range for the time period
CRC
Invalid CRC: the number of CRC errors out of range for the time period
PSC
Port hardware state changed too often due to fabric reconfiguration
STM
SFP temperature is out of specifications
SRX
SFP receive power is out of specifications
STX
SFP transmit power is out of specifications
SCU
SFP current is out of specifications
SVO
SFP voltage is out of specifications
Содержание StorageWorks 2/16 - SAN Switch
Страница 8: ...Contents 8 Fabric OS 3 x Document Addendum ...
Страница 16: ...Advanced performance monitor user guide 16 Fabric OS 3 x Document Addendum ...
Страница 22: ...Advanced Web Tools user guide 22 Fabric OS 3 x Document Addendum Figure 3 Switch status window port detail ...
Страница 72: ...Advanced Web Tools user guide 72 Fabric OS 3 x Document Addendum ...
Страница 130: ...Extended fabric user guide 130 Fabric OS 3 x Document Addendum ...
Страница 150: ...Fabric OS procedures user guide 150 Fabric OS 3 x Document Addendum ...
Страница 238: ...Fabric OS reference guide 238 Fabric OS 3 x Document Addendum ...