Page 1: ......

Page 2: ...This document was prepared and written by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON ...

Page 3: ...Recommended Touchpanel Cleaning 4 Applying Power 4 Identity Codes 5 Configuring the Touchpanel 5 Touchscreen Calibration Menu 6 Diagnostics Menu 6 Setup Menu 6 Programming 9 Uploading a VT Pro e Project 9 SIMPL Windows 11 Problem Solving 12 Troubleshooting 12 Further Inquiries 14 Future Updates 14 Appendix 15 Overview 15 VT Pro e Project 15 SIMPL Program 16 Conclusion How the Example Works 17 Retu...

Page 4: ......

Page 5: ...ack ST BTP of the touchpanel The STX 1550CW touchpanel offers 256 color display pop up subpages to reduce memory requirements providing optimal speed and performance multiple button and icon configurations up to 999 functions and 96 screens imported photographs drawings and icons support for downloadable fonts proportional and non proportional foreign language text When not docked in the DA 1550CW...

Page 6: ...to this address Instead refer to Further Inquiries on page 13 for assistance The STX 1550CW is supported by the VisionTools Pro e VT Pro e SmarTouch Wizard that automatically configures the entire system and the touchpanel pages VT Pro e a design and programming Windows based software permits the creation of unlimited control screen variations incorporating two and three dimensional graphics and t...

Page 7: ...l Crestron Database Version 12 1 4 or later 2 for SmarTouch Wizard support or 12 1 3 later 2 for regular support use a CT 1600 model CEN CN Update File Version 51180N UPZ or later 3 CNMSX AV Pro Update File Version 51020X UPZ or later 3 CNRACKX DP Update File Version 51020W UPZ or later 3 ST CP Update File Version 40104S UPZ or later 3 Default Timeouts One 1 minute for standby two 2 minutes for po...

Page 8: ...se harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures n Reorient or relocate the receiving antenna n Increase the separation between the equipment and receiver n Connect the equipment into an outlet on a circuit different from that to whi...

Page 9: ... from 03 to FE The NET ID of the unit must match the NET ID specified in the SIMPL Windows program RF ID Every STX 1550CW touchpanel communicating with a STRFGWX requires a unique RF ID to secure RF communications There are 15 useable codes for multiple touchpanel s ranging from 1 to F hexadecimal number The RF ID of the unit must match the RF ID specified in the SIMPL Windows program RF CHANNEL E...

Page 10: ...sible If you proceed to calibrate the touchpanel the screen prompts you with the message Touch Screen Calibration Menu nearly centered on the display Another message Touch Upper Left Corner appears in the upper left corner Touch the corner of the screen to initiate calibration Another message Touch Lower Right Corner appears in the lower right corner Touch the corner of the screen to return to the...

Page 11: ...reached NOTE The purpose of the Power Down Timeout is to maximize power pack battery life If the touchpanel is docked in the DA 1550CW docking assembly or utilizes an external AC power pack the panel does not power down when the power down timeout is achieved Standby timeout still functions Touch the RETURN button located in the bottom right corner of the screen to display the Setup Menu Interface...

Page 12: ...is identified by a hexadecimal number in the range from 0 to F In the diagram the RF CHANNEL is shown with a setting of 0 The DOWN and UP buttons associated with the RF ID field decrease and increase the RF ID by one respectively The TEST button should only be used under supervision from a Crestron customer service representative during telephone support The options available from the TEST Menu ar...

Page 13: ... project refer to the figures shown below and on the next page for typical connection diagrams Complete the following steps provided to ensure proper connection to the system NOTE If the control system in use has a 4 pin network connector rather than a modular RJ11 type NET connector use a ST CBL sold separately or make a cable Refer to the programming cable specifications diagram on the next page...

Page 14: ...ons to the touchpanel verify that control system is properly connected to the PC for ST CP use cable 15717 and adapter and powered on 2 Refer to the programming cable specifications diagram on the next page for connection to the NET port Attach the stereo connector end of the programming cable for ST CP use cable 15710 to the touchpanel 3 Attach the RJ11 connector end of the programming cable for ...

Page 15: ...or a Cresnet system Example Program The STX 1550CW and the STX 1550C non wall mounted touchpanel can be programmed identically Use the example program for the STX 1550C which is available from the Downloads page EXAMPLES Library of Crestron s website www crestron com Search for STX1550C SMW To see how to implement the STX 1550CW with the DA 1550CW search for DA1550CW ZIP New users are required to ...

Page 16: ...The table below and continued on the next page provides corrective action for possible trouble situations If further assistance is required please contact a Crestron customer service representative STX 1550CW Touchpanel Troubleshooting TROUBLE POSSIBLE CAUSE S CORRECTIVE ACTION Touchpanel does not function when docked Error caused by DA 1550CW Refer to Troubleshooting section of the latest revisio...

Page 17: ...the COM port being used to communicate to the control system NET ID on touchpanel is improperly set Verify that NET IDs match Refer to Interface in this Operations Guide and NET ID parameters assigned in the program Incorrect load selection Verify upload specifies correct NET ID and not Send Direct to Wired Touchpanel Touchpanel exhibits slow operation Compressed graphics take time to decompress I...

Page 18: ... America call Crestron Latin America at 525 260 4336 For local support from exclusive Crestron factory trained personnel call In Australia call Soundcorp at 613 9488 1555 In New Zealand call Amber Technologies at 649 410 8382 Future Updates As Crestron improves functions adds new features and extends the capabilities of the STX 1550CW additional information and programming examples may be made ava...

Page 19: ...of a control system that has three devices to control TV VCR and projector As such the VT Pro e project includes three pages one for each device Particular settings must be made on each device page to ensure proper functionality To support the goal of having the last page appear the program needs to be adjusted via SIMPL Windows This Appendix provides a SIMPL block diagram and description to chara...

Page 20: ...DOWN TIMEOUT Join Number Assignment In this example Press Here for TV Control Join 6 and Press Here for VCR Control Join 9 already have joined numbers assigned because they perform a function Only Press Here for Projector Control requires a new join number assignment Join 22 Each device page that is a destination of a page flip must be assigned a join number For this example the page join numbers ...

Page 21: ...anel the page flip setting on the buttons shown on the device pages can be removed via VT Pro e To illustrate how the example works consider the following actions taken by the user operating a STX touchpanel 1 While viewing the TV page of the VT Pro e project on the touchpanel the user touches the Press Here for Projector Control button 2 Join 22 feedback is activated which forces PROJ FLIP to log...

Page 22: ... of three 3 years from the date of shipment to purchaser Disk drives and any other moving or rotating mechanical parts are covered for a period of one 1 year Crestron warrants all its other products for a period of one year from the defects mentioned above excluding touchscreen display components which are covered for 90 days Incandescent lamps are completely excluded from Crestron s Limited Warra...

Page 23: ...Crestron STX 1550CW Wall Mount 2 Way RF Compact Color Touchpanel Operations Guide DOC 5849 Wall Mount 2 Way RF Compact Color Touchpanel STX 1550CW 19 This page intentionally left blank ...

Page 24: ...Crestron Electronics Inc Operations Guide DOC 5849 15 Volvo Drive Rockleigh NJ 07647 12 00 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...