Crestron Electronics, Inc.
Installation Guide – DOC. 6061
15 Volvo Drive
Pre-Construction Mount Kit: PMK-1000L
Rockleigh, NJ 07647
11.02
Tel: 888.CRESTRON
Specifications subject to change without notice.
Fax: 201.767.7576
www.crestron.com
Pre-Construction Mount Kit: PMK-1000L
The PMK-1000L is a pre-construction mount kit that has been developed for the Series 1000 Wall Mounted
Touchpanels. Refer to the physical views (top, side, and front) of the PMK-1000L, shown below.
2.41 in
(6.12 cm)
3.90 in
(9.92 cm)
0.34 in
(0.86 cm)
5.09 in
(12.92 cm)
4 7/16 in
(113 mm)
4 7/16 in
(113mm)
.06 in
(15.24 cm)
21/32 in
(17mm)
STUD OFFSET
PINS USED WITH
OPTIONAL MMK-1000L
#4-40 TAPPED HOLE
4 PLACES
FOR DRYWALL
NAIL
FOR DRYWALL
SCREW
FOR DRYWALL NAIL
FOR DRYWALL
SCREW
FOR DRYWALL
NAIL
CUTOUT
DIMENSIONS
SECURE 18 AWG BUS WIRE IN
NOTCH TO HANG CABLES AWAY
FROM DRYWALL CUTTING TOOLS
PRE-CONSTRUCTION PLATE
MUST BE LEVEL BEFORE
APPLICATION OF DRYWALL
7.31 in
(18.57 cm)
5.77 in
(14.66 cm)
2.88 in
(7.31 cm)
1.00 in
(2.54 cm)
STUD
PMK-1000L
Assembled View
The PMK-1000L consists of a single metal plate, shown above, which can be fastened to the stud of a framed wall
prior to hanging drywall. The plate is designed to provide the necessary support for a single touchpanel and can
mount to the right or left side of a stud. Standard drywall nails or screws to attach the PMK-1000L are not supplied
(length can vary). The PMK-1000L includes an 18 AWG bus wire to secure touchpanel cabling during drywall
installation and to avoid damaging the cables when the opening is routed. Confirm that the PMK-1000L is level
before application of sheet rock.
NOTE:
This device must be installed in accordance with local building codes.
A rectangular opening with the dimensions shown above must be made in the drywall. Verify that the opening
exposes the #4-40 tapped holes in each corner. Complete the installation by either installing the touchpanel, leaving
the hole open (if permitted by local building codes), or installing the supplied cover plate with the supplied
#4-40 x 1½” screws.
If the opening for the touchpanel in the drywall is too large, two pre-construction accessories are available to make
adjustments. Use the optional TMK-1000L (Trim Ring Kit) to provide a smooth edge at the opening. This option
provides a finished appearance and is preferred when wallpaper is hung. Use the optional MMK-1000L (Mud Ring
Kit) to fill in larger irregularities around the opening (requires plastering).
Further Inquiries
If after reviewing this sheet, you cannot locate specific information or have questions, please take advantage of
Crestron's award winning customer service team by calling:
•
In the US and Canada, call Crestron’s corporate headquarters at
1-888-CRESTRON [1-888-273-7876].
•
In Europe, call Crestron International at +32-15-50-99-50.
•
In Asia, call Crestron Asia at +852-2341-2016.
•
In Latin America, call Crestron Latin America at +5255-5093-2160.
•
In Australia and New Zealand, call Crestron Pacific at +613-9480-2999.
As of the date of manufacture, the PMK-3000L has been tested and found to comply with specifications for CE
marking.