SROS Command Line Interface Reference Guide
Frame Relay Interface Config Command Set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
882
frame-relay lmi-n391dce
<polls>
Use the
frame-relay lmi-n391dce
command to set the N391 full status polling counter for the DCE
endpoint. Typical applications should leave the default value for this timer. Use the
no
form of this
command to return to the default value.
Syntax Description
<polls>
Sets the counter value (Range: 1 to 255).
Default Values
By default, the polling counter for the DCE endpoint is set to six polls.
Functional Notes
The N391 counter determines how many link integrity polls occur in between full status polls. The number
of link integrity polls between full status polls is n - 1, where n represents the full status poll. n can be set to
any number between 1 and 255, but the default is used for most applications.
Usage Examples
The following example sets the N391 counter for three polls:
ProCurve(config)#
interface frame-relay 1
ProCurve(config-fr 1)#
frame-relay lmi-n391dce 3