SROS Command Line Interface Reference Guide
Common Commands
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
1433
ProCurve(config-fr 7)#
interface fr 7.22
ProCurve(config-fr 7.22)#
frame-relay interface-dlci 30
ProCurve(config-fr 7.22)#
ip address 193.44.69.253 255.255.255.252
Step 3:
Specify the group of DS0s used for signaling on the T1 interface by creating a
tdm-group
. Group any
number of contiguous DS0s together to create a data pipe for layer 2 signaling. Also use the
tdm-group
command to specify the per-DS0 signaling rate on the interface. For example, the following creates a
tdm-group labeled
9
containing 20 DS0s (each DS0 having a data rate of 56 kbps).
ProCurve(config)#
interface t1 1/1
ProCurve(config-t1 1/1)#
tdm-group 9 timeslots 1-20 speed 56
ProCurve(config-t1 1/1)#
exit
Step 4:
Make the association between the layer 2 endpoint and the physical interface using the
bind
command.
Supported layer 2 protocols include Frame Relay and point-to-point protocol (PPP). For example, the
following creates a bind (labeled
5
) to make an association between the Frame Relay virtual interface (
fr 7
)
and the tdm-group configured on interface t1 1/1 (
tdm-group 9
).
ProCurve(config)#
bind 5 t1 1/1 9 fr 7
Содержание ProCurve Secure 7102dl