loopback remote v54
The
loopback remove v54
command initiates an E1 remote loopback test (with a V.54 loopback pattern).
Use the
no
form of this command to deactivate the loopback.
Syntax Description
No subcommands.
Default Values
No default value is necessary for this command.
Functional Notes
This command causes a V.54 inband loop code to be sent in the payload towards the far end.
Usage Examples
The following example sends a V.54 inband loop code to the far end:
ProCurve(config)#
interface e1 1/1
ProCurve(config-e1 1/1)#
loopback remote v54