SROS Command Line Interface Reference Guide
Frame Relay Interface Config Command Set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
884
frame-relay lmi-n392dce
<threshold>
Use the
frame-relay lmi-n392dce
command to set the N392 error threshold for the DCE endpoint. Typical
applications should leave the default value for this setting. Use the
no
form of this command to return to
the default value.
Syntax Description
<threshold>
Sets the threshold value (Range: 1 to 10).
Default Values
By default, the error threshold for the DCE endpoint is set to three errors.
Functional Notes
If the error threshold is met, the signaling state status is changed to down, indicating a service-affecting
condition. This condition is cleared once N393 consecutive error-free events are received. N392 defines
the number of errors required in a given event window, while N393 defines the number of polling events in
each window.
For example:
If N392=3 and N393=4, then if three errors occur within any four events, the interface is determined
inactive.
Usage Examples
The following example sets the N392 threshold for 5 seconds:
ProCurve(config)#
interface frame-relay 1
ProCurve(config-fr 1)#
frame-relay lmi-n392dce 5
Содержание ProCurve Secure 7102dl